RADIK PLAN VKM is a steel panel radiator which enables a bottom middle connection to the pressurized heating system. There are two upper and two lower hangers welded at the back of the radiator. Radiators in length 1800 mm long and more have six hangers. RADIK PLAN VKM radiators are supplied with an air vent, two blanking plugs and a valve with a plastic cap.

Technical Data

Height (H) 300, 400, 500, 600, 900 mm
Length (L) 400, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600, 1800, 2000 mm
Depth (B)
- Type 11 PLAN VKM 65 mm
- Type 21 PLAN VKM 68 mm
- Type 22 PLAN VKM 102 mm
- Type 33 PLAN VKM 157 mm
Connecting pitch 50 mm
Connecting thread 6 × G½ inside
Highest allowed working pressure 10 bar
Highest allowed working temperature (°C) 110 °C
Radiator connection middle connection
Pressure Loss

In case of two-pipe heating system it is necessary to calculate the correct level of valve presetting and specify this in the project documentation to ensure a proper function of the heating system. This must be kept by the installer during installation of the heating system.

In case of one-pipe heating system it is necessary to set the valve at level 6. For adjusting the required mass flow in the radiator we recommend to use the compact connecting fitting with a fixed or adjustable flow volume of water in the radiator.


Heat output [W]

Heat output calculated to ∆T= 50; (t1/t2/ti = for 75/65/20 °C)

Type 11 PLAN VKM Type 21 PLAN VKM Type 22 PLAN VKM Type 33 PLAN VKM
Height [mm] Height [mm] Height [mm] Height [mm]
Length [mm] 300 400 500 600 900 300 400 500 600 900 300 400 500 600 900 300 400 500 600 900
400 212 263 312 359 492 288 362 429 490 647 366 466 560 648 886
500 265 329 390 449 616 360 452 536 613 809 457 583 700 811 1108 1011 1171 1616
600 318 395 468 538 739 432 542 643 736 970 548 699 840 973 1329 1213 1405 1939
700 371 461 546 628 862 504 633 750 858 1132 640 816 980 1135 1551 1415 1639 2262
800 424 526 624 718 985 576 723 858 981 1294 731 932 1120 1297 1772 1070 1351 1618 1873 2585
900 477 592 702 807 1108 648 814 965 1103 1455 823 1049 1260 1459 1994 1203 1520 1820 2107 2908
1000 530 658 780 897 1231 720 904 1072 1226 1617 914 1165 1400 1621 2215 1337 1689 2022 2341 3231
1100 583 724 858 987 792 994 1179 1349 1779 1005 1282 1540 1783 2437 1471 1858 2224 2575 3554
1200 636 790 936 1076 864 1085 1286 1471 1940 1097 1398 1680 1945 2658 1604 2027 2426 2809 3877
1400 742 921 1092 1256 1008 1266 1501 1716 2264 1280 1631 1960 2269 3101 1872 2365 2831 3277 4523
1600 848 1053 1248 1435 1152 1446 1715 1962 2587 1462 1864 2240 2594 3544 2139 2702 3235 3746 5170
1800 954 1184 1404 1615 1296 1627 1930 2207 1645 2097 2520 2918 2407 3040 3640 4214
2000 1060 1316 1560 1794 1440 1808 2144 2452 1828 2330 2800 3242 2674 3378 4044 4682